Hikvision DS-UPS-R/AU — Line-Interactive Back-Up UPS with AVR & Cold Start for CCTV, NVR, POS & Network Systems (600VA / 1000VA / 2000VA)

Description

Hikvision DS-UPS-R/AU · Line-Interactive · AVR · Cold Start · 600 / 1000 / 2000 VA Hikvision DS-UPS-R/AU Range

Hikvision DS-UPS-R/AU Series — Line-Interactive Back-Up UPS with AVR for CCTV & NVR Systems

The Hikvision DS-UPS-R/AU range is a line of line-interactive tower UPS units designed to keep your CCTV recording running through mains dropouts, brownouts and dirty power. Available in 600 VA / 360 W (small residential NVRs), 1000 VA / 600 W (mainstream commercial NVR + camera load) and 2000 VA / 1200 W (large PoE switches, multi-HDD NVRs, larger sites). Built-in Automatic Voltage Regulation (AVR) corrects mains sag and surge without dropping to battery, so the batteries only discharge during actual outages — extending battery life. Cold start lets you power the NVR from battery even when there's no mains at all (useful for planned outages). Every unit is rated at 230 VAC 50 Hz, ships with Australian mains plug + AU-standard IEC outlets, and is backed by 3-year Australian warranty from CCTV Guru.

Topology
Line-Interactive · AVR
Capacity Range
600 VA · 1000 VA · 2000 VA
Input / Output
230 VAC 50 Hz · AU Plug + IEC
Cold Start
Power on from Battery · No Mains Needed
Protection
Surge · Overload · Short-Circuit · RJ11
Warranty
3-Year AU · Battery Replaceable
3-Year AU Warranty
Fast AU Shipping
Australian Tech Support

Why a UPS Matters for a CCTV or NVR System

Every CCTV recorder has a hard drive that's writing continuously. When the mains flicks off mid-write — a lightning strike, a substation dip, someone tripping the RCD — the HDD doesn't get to flush its cache before the power dies. The result is corrupted footage, index errors, or in the worst case a bricked RAID array. A UPS gives the NVR 5-15 minutes of clean battery power on an outage; the NVR shuts down cleanly (via USB signalling on models that support it), the HDD flushes properly, and there's no corruption when the power comes back. Line-interactive UPS units go one better — they use AVR (Automatic Voltage Regulation) to smooth out mains sag and surge without discharging the battery, so battery life is preserved for the times you actually need it.

Line-Interactive Topology with AVR

Automatic Voltage Regulation corrects ±25% mains sag and surge without switching to battery. Extends battery lifespan (typical AU regional grid has 30-50 minor sag events per week that would otherwise cycle a cheap standby UPS to battery).

Cold Start Capability

Start the load from battery even when there's no mains at all. Useful for planned outages (running a camera off-grid for a temporary site check) or bringing up the NVR after an extended power failure while the mains is still being restored.

USB Auto-Shutdown Signalling

Micro-USB connection to the NVR — when battery drops below the safe threshold, the UPS signals the NVR to shut down cleanly. Works with most Hikvision NVRs out of the box (may require enabling in NVR settings).

Full Range of Protections

Overload, short-circuit, over-discharge, over-charge, and mains surge protection — plus RJ11 telephone / network surge protection pass-through on all models to protect ADSL/NBN modems.

Replaceable Battery

Sealed lead-acid battery module accessible via bottom cover — replaceable at end of life (typical 3-5 years, faster in high ambient temp). Uses standard 12 V SLA batteries (600 VA: 12 V 4.5 Ah, 1000 VA: 12 V 9 Ah, 2000 VA: 2 × 12 V 9 Ah).

Silent Fan-Free Operation (600 & 1000 VA)

The 600 VA and 1000 VA models are fan-free — silent when running from mains. Suitable for reception desks, home offices, sleeping areas. The 2000 VA has a low-noise thermally-controlled fan that only runs at high load or on battery.

Capacity Guide — Which VA Rating for Which NVR?

UPS runtime is capped by the smaller of two things: the load in watts (must be under the UPS's watt rating) and the battery capacity. Below is a practical sizing guide based on Hikvision's own NVR power consumption.

Sizing Guide · Which UPS for Which NVR
600 VA / 360 W · $101 4-8 channel M-Series NVRs with 1 HDD. Small residential / single-camera commercial. NVR draw ~40-60 W → ~15-20 min runtime.
1000 VA / 600 W · $149 (most popular) 8-16 channel NVRs with 1-2 HDD + a small PoE switch. Mainstream commercial. NVR + 8 cameras ~120-180 W → ~15-25 min runtime.
2000 VA / 1200 W · $269 16-32 channel NVRs with 2-4 HDD, larger PoE-heavy sites, DeepinMind AI NVRs. Also fits sites with modem + NVR + monitor + PoE switch. ~15-30 min runtime at typical load.

Rule of thumb: add up the wattage of everything you want protected (NVR + PoE switch + modem + a small monitor if used), then pick the UPS that's at least 1.5× that number in watts. Sizing headroom = longer runtime + longer battery life.

Full Specifications Comparison

DS-UPS-R/AU Range · Specification Comparison
Spec 600 VA · 360 W · $101  |  1000 VA · 600 W · $149  |  2000 VA · 1200 W · $269
SKU DS-UPS600-R/AU · DS-UPS1000-R/AU · DS-UPS2000-R/AU
Topology Line-Interactive with AVR (all three)
Capacity 600 VA / 360 W · 1000 VA / 600 W · 2000 VA / 1200 W
Input Voltage 230 VAC (140-300 VAC operating range) 50 Hz (all three)
Output Voltage 230 VAC ±10% (battery mode) · simulated sine wave
Transfer Time Typically ≤ 6 ms (all three)
Battery 12 V 4.5 Ah SLA · 12 V 9 Ah SLA · 2× 12 V 9 Ah SLA
Recharge Time ≤ 8 hours to 90% (all three)
Output Sockets 2× IEC (AU) · 3× IEC (AU) · 4× IEC (AU) + optional 15 A AU socket on 2000 VA
Communication USB (auto-shutdown) · RJ11 surge pass-through (all three)
Cold Start Yes (all three)
Cooling Passive (fan-free) · Passive (fan-free) · Low-noise thermal fan
Efficiency (AC mode) ≥ 92% (all three)
Operating Temperature 0 °C to +40 °C · humidity ≤90 % (non-condensing)
Dimensions (approx.) 90×140×195 mm · 100×145×280 mm · 145×195×340 mm
Weight ~4.5 kg · ~7.5 kg · ~14 kg
Certifications RCM (AU) · CE · RoHS
Warranty 3-Year Australian Warranty (all three)

Frequently Asked Questions

What's the difference between VA and Watts?

VA (volt-amps) is the apparent power rating; Watts is the real power the UPS can deliver. For CCTV/NVR loads, the wattage number is what actually matters — that's what you compare against the actual draw of your equipment. VA is what UPS marketing leads with because it's a bigger number.

How long will the UPS run my NVR for?

Depends on load. A typical 8-camera Hikvision NVR draws ~120-180 W. At half load, the 1000 VA runs 15-25 min, the 2000 VA runs 25-40 min, and the 600 VA runs 5-10 min. Enough for a clean shutdown; not enough to keep recording through a multi-hour outage. For that, you want a larger UPS or a solar / genset solution.

Can it auto-shutdown my NVR?

Yes — connect the USB cable from the UPS to the NVR's USB port and enable UPS shutdown in the NVR settings. When the battery drops to the safe threshold, the UPS signals the NVR to save-and-shutdown. Works with most Hikvision NVRs; check the NVR's user manual for the exact menu path.

Does it protect my ADSL/NBN modem too?

Yes — plug the modem into one of the UPS's IEC outlets to power-protect it, AND run your ADSL/phone line through the RJ11 surge pass-through ports on the back to protect against surges coming down the phone line (lightning strikes on the copper network often destroy modems).

How often do I need to replace the battery?

Typical SLA battery life is 3-5 years in Australian ambient conditions. Batteries in hot spaces (comms cabinets in summer) may only last 2-3 years. The UPS beeps when the battery fails its self-test — that's your signal. Replacement batteries are standard 12 V SLA sizes available from any battery supplier.

What's a "sine wave" vs "simulated sine wave" output?

Pure sine wave outputs are true smooth AC — required by some sensitive equipment (medical, some audio gear). Simulated sine wave (also called modified sine wave) is what the DS-UPS-R/AU uses — perfectly fine for NVRs, PoE switches, modems, monitors, computers and 99% of home / commercial IT gear.

Order the Hikvision DS-UPS-R/AU from CCTV Guru

Australian stock across the entire DS-UPS-R/AU range — 600 VA, 1000 VA and 2000 VA. Select your capacity from the dropdown above. Free tech advice on sizing for your specific NVR + camera load — contact us with your parts list and we'll spec the right UPS for your project. Multi-unit and installer pricing available for site rollouts and body-corp maintenance contracts. Request a free quote or contact our Australian team.

Hikvision DS-UPS-R/AU — Line-Interactive Back-Up UPS with AVR & Cold Start for CCTV, NVR, POS & Network Systems (600VA / 1000VA / 2000VA)

Product form

SKU: DS-UPS1000-R/AU

$199.00  $149.00 Incl. GST

    • PayPal
    • Apple Pay
    • Visa
    • Mastercard
    • American Express
    • Zip
    • Afterpay

    • Shipped today? Order within: Jul 23, 2026 14:00:00 +1000
    • Warranty: 24 months
    • 30 day Money Back Guarantee
    • Australian Stocks & Express Delivery
    • Back-to-base Warranty & Tech Support
    • FREE Shipping over $180

    Description

    Hikvision DS-UPS-R/AU · Line-Interactive · AVR · Cold Start · 600 / 1000 / 2000 VA Hikvision DS-UPS-R/AU Range

    Hikvision DS-UPS-R/AU Series — Line-Interactive Back-Up UPS with AVR for CCTV & NVR Systems

    The Hikvision DS-UPS-R/AU range is a line of line-interactive tower UPS units designed to keep your CCTV recording running through mains dropouts, brownouts and dirty power. Available in 600 VA / 360 W (small residential NVRs), 1000 VA / 600 W (mainstream commercial NVR + camera load) and 2000 VA / 1200 W (large PoE switches, multi-HDD NVRs, larger sites). Built-in Automatic Voltage Regulation (AVR) corrects mains sag and surge without dropping to battery, so the batteries only discharge during actual outages — extending battery life. Cold start lets you power the NVR from battery even when there's no mains at all (useful for planned outages). Every unit is rated at 230 VAC 50 Hz, ships with Australian mains plug + AU-standard IEC outlets, and is backed by 3-year Australian warranty from CCTV Guru.

    Topology
    Line-Interactive · AVR
    Capacity Range
    600 VA · 1000 VA · 2000 VA
    Input / Output
    230 VAC 50 Hz · AU Plug + IEC
    Cold Start
    Power on from Battery · No Mains Needed
    Protection
    Surge · Overload · Short-Circuit · RJ11
    Warranty
    3-Year AU · Battery Replaceable
    3-Year AU Warranty
    Fast AU Shipping
    Australian Tech Support

    Why a UPS Matters for a CCTV or NVR System

    Every CCTV recorder has a hard drive that's writing continuously. When the mains flicks off mid-write — a lightning strike, a substation dip, someone tripping the RCD — the HDD doesn't get to flush its cache before the power dies. The result is corrupted footage, index errors, or in the worst case a bricked RAID array. A UPS gives the NVR 5-15 minutes of clean battery power on an outage; the NVR shuts down cleanly (via USB signalling on models that support it), the HDD flushes properly, and there's no corruption when the power comes back. Line-interactive UPS units go one better — they use AVR (Automatic Voltage Regulation) to smooth out mains sag and surge without discharging the battery, so battery life is preserved for the times you actually need it.

    Line-Interactive Topology with AVR

    Automatic Voltage Regulation corrects ±25% mains sag and surge without switching to battery. Extends battery lifespan (typical AU regional grid has 30-50 minor sag events per week that would otherwise cycle a cheap standby UPS to battery).

    Cold Start Capability

    Start the load from battery even when there's no mains at all. Useful for planned outages (running a camera off-grid for a temporary site check) or bringing up the NVR after an extended power failure while the mains is still being restored.

    USB Auto-Shutdown Signalling

    Micro-USB connection to the NVR — when battery drops below the safe threshold, the UPS signals the NVR to shut down cleanly. Works with most Hikvision NVRs out of the box (may require enabling in NVR settings).

    Full Range of Protections

    Overload, short-circuit, over-discharge, over-charge, and mains surge protection — plus RJ11 telephone / network surge protection pass-through on all models to protect ADSL/NBN modems.

    Replaceable Battery

    Sealed lead-acid battery module accessible via bottom cover — replaceable at end of life (typical 3-5 years, faster in high ambient temp). Uses standard 12 V SLA batteries (600 VA: 12 V 4.5 Ah, 1000 VA: 12 V 9 Ah, 2000 VA: 2 × 12 V 9 Ah).

    Silent Fan-Free Operation (600 & 1000 VA)

    The 600 VA and 1000 VA models are fan-free — silent when running from mains. Suitable for reception desks, home offices, sleeping areas. The 2000 VA has a low-noise thermally-controlled fan that only runs at high load or on battery.

    Capacity Guide — Which VA Rating for Which NVR?

    UPS runtime is capped by the smaller of two things: the load in watts (must be under the UPS's watt rating) and the battery capacity. Below is a practical sizing guide based on Hikvision's own NVR power consumption.

    Sizing Guide · Which UPS for Which NVR
    600 VA / 360 W · $101 4-8 channel M-Series NVRs with 1 HDD. Small residential / single-camera commercial. NVR draw ~40-60 W → ~15-20 min runtime.
    1000 VA / 600 W · $149 (most popular) 8-16 channel NVRs with 1-2 HDD + a small PoE switch. Mainstream commercial. NVR + 8 cameras ~120-180 W → ~15-25 min runtime.
    2000 VA / 1200 W · $269 16-32 channel NVRs with 2-4 HDD, larger PoE-heavy sites, DeepinMind AI NVRs. Also fits sites with modem + NVR + monitor + PoE switch. ~15-30 min runtime at typical load.

    Rule of thumb: add up the wattage of everything you want protected (NVR + PoE switch + modem + a small monitor if used), then pick the UPS that's at least 1.5× that number in watts. Sizing headroom = longer runtime + longer battery life.

    Full Specifications Comparison

    DS-UPS-R/AU Range · Specification Comparison
    Spec 600 VA · 360 W · $101  |  1000 VA · 600 W · $149  |  2000 VA · 1200 W · $269
    SKU DS-UPS600-R/AU · DS-UPS1000-R/AU · DS-UPS2000-R/AU
    Topology Line-Interactive with AVR (all three)
    Capacity 600 VA / 360 W · 1000 VA / 600 W · 2000 VA / 1200 W
    Input Voltage 230 VAC (140-300 VAC operating range) 50 Hz (all three)
    Output Voltage 230 VAC ±10% (battery mode) · simulated sine wave
    Transfer Time Typically ≤ 6 ms (all three)
    Battery 12 V 4.5 Ah SLA · 12 V 9 Ah SLA · 2× 12 V 9 Ah SLA
    Recharge Time ≤ 8 hours to 90% (all three)
    Output Sockets 2× IEC (AU) · 3× IEC (AU) · 4× IEC (AU) + optional 15 A AU socket on 2000 VA
    Communication USB (auto-shutdown) · RJ11 surge pass-through (all three)
    Cold Start Yes (all three)
    Cooling Passive (fan-free) · Passive (fan-free) · Low-noise thermal fan
    Efficiency (AC mode) ≥ 92% (all three)
    Operating Temperature 0 °C to +40 °C · humidity ≤90 % (non-condensing)
    Dimensions (approx.) 90×140×195 mm · 100×145×280 mm · 145×195×340 mm
    Weight ~4.5 kg · ~7.5 kg · ~14 kg
    Certifications RCM (AU) · CE · RoHS
    Warranty 3-Year Australian Warranty (all three)

    Frequently Asked Questions

    What's the difference between VA and Watts?

    VA (volt-amps) is the apparent power rating; Watts is the real power the UPS can deliver. For CCTV/NVR loads, the wattage number is what actually matters — that's what you compare against the actual draw of your equipment. VA is what UPS marketing leads with because it's a bigger number.

    How long will the UPS run my NVR for?

    Depends on load. A typical 8-camera Hikvision NVR draws ~120-180 W. At half load, the 1000 VA runs 15-25 min, the 2000 VA runs 25-40 min, and the 600 VA runs 5-10 min. Enough for a clean shutdown; not enough to keep recording through a multi-hour outage. For that, you want a larger UPS or a solar / genset solution.

    Can it auto-shutdown my NVR?

    Yes — connect the USB cable from the UPS to the NVR's USB port and enable UPS shutdown in the NVR settings. When the battery drops to the safe threshold, the UPS signals the NVR to save-and-shutdown. Works with most Hikvision NVRs; check the NVR's user manual for the exact menu path.

    Does it protect my ADSL/NBN modem too?

    Yes — plug the modem into one of the UPS's IEC outlets to power-protect it, AND run your ADSL/phone line through the RJ11 surge pass-through ports on the back to protect against surges coming down the phone line (lightning strikes on the copper network often destroy modems).

    How often do I need to replace the battery?

    Typical SLA battery life is 3-5 years in Australian ambient conditions. Batteries in hot spaces (comms cabinets in summer) may only last 2-3 years. The UPS beeps when the battery fails its self-test — that's your signal. Replacement batteries are standard 12 V SLA sizes available from any battery supplier.

    What's a "sine wave" vs "simulated sine wave" output?

    Pure sine wave outputs are true smooth AC — required by some sensitive equipment (medical, some audio gear). Simulated sine wave (also called modified sine wave) is what the DS-UPS-R/AU uses — perfectly fine for NVRs, PoE switches, modems, monitors, computers and 99% of home / commercial IT gear.

    Order the Hikvision DS-UPS-R/AU from CCTV Guru

    Australian stock across the entire DS-UPS-R/AU range — 600 VA, 1000 VA and 2000 VA. Select your capacity from the dropdown above. Free tech advice on sizing for your specific NVR + camera load — contact us with your parts list and we'll spec the right UPS for your project. Multi-unit and installer pricing available for site rollouts and body-corp maintenance contracts. Request a free quote or contact our Australian team.

    Login

    Forgot your password?

    Don't have an account yet?
    Create account