{"product_id":"hikvision-ds-k2m002x-2-door-access-control-module","title":"Hikvision DS-K2M002X 2-Door Access Control Expansion Module","description":"\u003cdiv class=\"cg-premium-wrap\"\u003e\n\n  \u003cspan class=\"cg-badge\"\u003eAccess Control Module · 2-Door Expansion · DS-K2700X Ready\u003c\/span\u003e\n\n  \u003ch2\u003eHikvision DS-K2M002X 2-Door Access Control Expansion Module\u003c\/h2\u003e\n\n  \u003cp\u003eThe \u003cstrong\u003eHikvision DS-K2M002X\u003c\/strong\u003e is a professional \u003cstrong\u003e2-door access control expansion module\u003c\/strong\u003e designed to extend compatible Hikvision access controllers, including the DS-K2700X \/ DS-K2704X platform. It connects to the main access controller via \u003cstrong\u003eRS-485\u003c\/strong\u003e and provides lock control, exit button input, door contact input, alarm input\/output and reader connection for additional doors.\u003c\/p\u003e\n\n  \u003cp\u003eThis module is ideal for Australian commercial buildings, schools, warehouses, strata sites, offices and multi-door access control projects where the system needs to expand beyond the controller’s native door capacity. It supports card readers via \u003cstrong\u003eRS-485 OSDP\u003c\/strong\u003e or \u003cstrong\u003eWiegand\u003c\/strong\u003e, installs neatly with guide rail mounting and supports battery charge\/discharge through the access control system design.\u003c\/p\u003e\n\n  \u003cdiv class=\"cg-feature-strip\"\u003e\n\n    \u003cdiv class=\"cg-feature-pill\"\u003e\n      \u003cdiv class=\"cg-feature-pill__icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003crect x=\"3\" y=\"4\" width=\"18\" height=\"16\" rx=\"2\"\u003e\u003c\/rect\u003e\u003cpath d=\"M7 8h10M7 12h10M7 16h6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n      \u003cdiv class=\"cg-feature-pill__text\"\u003e\n        \u003cdiv class=\"cg-feature-pill__label\"\u003eModel\u003c\/div\u003e\n        \u003cdiv class=\"cg-feature-pill__value\"\u003eDS-K2M002X\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-pill\"\u003e\n      \u003cdiv class=\"cg-feature-pill__icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M5 21V5a2 2 0 0 1 2-2h10a2 2 0 0 1 2 2v16\"\u003e\u003c\/path\u003e\u003cpath d=\"M9 21v-6h6v6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n      \u003cdiv class=\"cg-feature-pill__text\"\u003e\n        \u003cdiv class=\"cg-feature-pill__label\"\u003eDoor Control\u003c\/div\u003e\n        \u003cdiv class=\"cg-feature-pill__value\"\u003e2 Doors\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-pill\"\u003e\n      \u003cdiv class=\"cg-feature-pill__icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M4 6h16v12H4z\"\u003e\u003c\/path\u003e\u003cpath d=\"M8 10h8M8 14h8\"\u003e\u003c\/path\u003e\u003cpath d=\"M4 9H2M4 15H2M22 9h-2M22 15h-2\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n      \u003cdiv class=\"cg-feature-pill__text\"\u003e\n        \u003cdiv class=\"cg-feature-pill__label\"\u003eController Link\u003c\/div\u003e\n        \u003cdiv class=\"cg-feature-pill__value\"\u003eRS-485\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-pill\"\u003e\n      \u003cdiv class=\"cg-feature-pill__icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M4 7h16\"\u003e\u003c\/path\u003e\u003cpath d=\"M4 12h16\"\u003e\u003c\/path\u003e\u003cpath d=\"M4 17h16\"\u003e\u003c\/path\u003e\u003cpath d=\"M7 7v10M17 7v10\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n      \u003cdiv class=\"cg-feature-pill__text\"\u003e\n        \u003cdiv class=\"cg-feature-pill__label\"\u003eReaders\u003c\/div\u003e\n        \u003cdiv class=\"cg-feature-pill__value\"\u003eOSDP · Wiegand\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-pill\"\u003e\n      \u003cdiv class=\"cg-feature-pill__icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M6 9v6a6 6 0 0 0 12 0V9\"\u003e\u003c\/path\u003e\u003cpath d=\"M9 9V5a3 3 0 0 1 6 0v4\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n      \u003cdiv class=\"cg-feature-pill__text\"\u003e\n        \u003cdiv class=\"cg-feature-pill__label\"\u003eLock Outputs\u003c\/div\u003e\n        \u003cdiv class=\"cg-feature-pill__value\"\u003e2 Lock Controls\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-pill\"\u003e\n      \u003cdiv class=\"cg-feature-pill__icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M13 2 4 14h7l-1 8 10-13h-7z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n      \u003cdiv class=\"cg-feature-pill__text\"\u003e\n        \u003cdiv class=\"cg-feature-pill__label\"\u003ePower\u003c\/div\u003e\n        \u003cdiv class=\"cg-feature-pill__value\"\u003e12V DC\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cg-trust-strip cg-trust-strip--dark\"\u003e\n    \u003cdiv class=\"cg-trust-item\"\u003e\n      \u003cspan class=\"cg-trust-icon\"\u003e\u003csvg viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M20 7 9 18l-5-5\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/span\u003e\n      \u003cspan class=\"cg-trust-title\"\u003eGenuine Hikvision\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cg-trust-item\"\u003e\n      \u003cspan class=\"cg-trust-icon\"\u003e\u003csvg viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M12 2 4 6v6c0 5 3.5 8.5 8 10 4.5-1.5 8-5 8-10V6z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/span\u003e\n      \u003cspan class=\"cg-trust-title\"\u003eCommercial Grade\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cg-trust-item\"\u003e\n      \u003cspan class=\"cg-trust-icon\"\u003e\u003csvg viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M3 11h18\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 11V7a7 7 0 0 1 14 0v4\"\u003e\u003c\/path\u003e\u003crect x=\"3\" y=\"11\" width=\"18\" height=\"10\" rx=\"2\"\u003e\u003c\/rect\u003e\u003c\/svg\u003e\u003c\/span\u003e\n      \u003cspan class=\"cg-trust-title\"\u003eAustralian Support\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eWhy Choose the DS-K2M002X?\u003c\/h2\u003e\n\n  \u003cdiv class=\"cg-feature-grid\"\u003e\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eExpand Hikvision Controller Capacity\u003c\/span\u003e\n      Add 2 additional doors to compatible Hikvision access controller systems, making it a practical expansion module for staged commercial projects.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eDesigned for DS-K2700X Projects\u003c\/span\u003e\n      Ideal companion module for DS-K2700X \/ DS-K2704X access controller deployments where the system needs to scale beyond the controller’s native doors.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eReader Flexibility\u003c\/span\u003e\n      Connect compatible readers via RS-485 OSDP or Wiegand, giving installers flexibility across different door and reader layouts.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eComplete Door I\/O\u003c\/span\u003e\n      Each module provides lock control, exit button input, door contact input, alarm input\/output and tamper input for professional access control wiring.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eGuide Rail Installation\u003c\/span\u003e\n      Designed for neat installation inside access control enclosures, equipment cabinets and commercial security panels.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eBattery Charge \/ Discharge Support\u003c\/span\u003e\n      Supports battery charge and discharge functions as part of a correctly designed access control power system.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eRecommended For\u003c\/h2\u003e\n\n  \u003cdiv class=\"cg-feature-grid\"\u003e\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eCommercial Buildings\u003c\/span\u003e\n      Expand door control across staff entries, tenancy doors, lift lobbies, plant rooms and restricted areas.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eSchools \u0026amp; Education Sites\u003c\/span\u003e\n      Add controlled access to classrooms, administration areas, gates, libraries and staff-only zones.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eWarehouses \u0026amp; Industrial Sites\u003c\/span\u003e\n      Secure loading docks, cages, stockrooms, staff doors and office entries with centralised access control.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eStrata \u0026amp; Apartment Buildings\u003c\/span\u003e\n      Expand access control for car parks, lobbies, bin rooms, shared amenities and back-of-house service doors.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eHealthcare \u0026amp; Clinics\u003c\/span\u003e\n      Add access-controlled doors for treatment rooms, medication areas, staff corridors and secure administration areas.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eLarge Multi-Door Projects\u003c\/span\u003e\n      Use multiple DS-K2M002X modules to build scalable access control systems across larger sites.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eTypical Deployment Example\u003c\/h2\u003e\n\n  \u003cp\u003eThe DS-K2M002X is commonly used with a Hikvision access controller when a site needs additional doors beyond the controller’s built-in capacity. Each module supports 2 linked doors and connects back to the controller via RS-485.\u003c\/p\u003e\n\n  \u003cdiv class=\"cg-feature-grid\"\u003e\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003e1 × Main Access Controller\u003c\/span\u003e\n      Use with a compatible Hikvision access controller such as a DS-K2700X Series controller to manage users, events and access rules.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003e1 × DS-K2M002X Module\u003c\/span\u003e\n      Adds 2 linked doors with lock control, exit button input, door contact input and reader connection.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eReaders or Terminals\u003c\/span\u003e\n      Connect compatible card readers via RS-485 OSDP or Wiegand depending on the project design.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eDoor Hardware\u003c\/span\u003e\n      Complete each door with electric strike or magnetic lock, exit button, reed switch and suitable access control power supply.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eRecommended Accessories\u003c\/h2\u003e\n\n  \u003cdiv class=\"cg-feature-grid\"\u003e\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eDS-K2704X Enterprise Controller\u003c\/span\u003e\n      Main access controller for larger commercial systems where multiple DS-K2M002X modules may be required.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eHikvision Card Readers\u003c\/span\u003e\n      Pair with compatible RS-485 OSDP or Wiegand card readers for staff entry and secure door access.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eDS-K1T502DBWX-CQRE1 Terminal\u003c\/span\u003e\n      Use QR, card, PIN, Bluetooth and intercom-style access terminals where smarter door entry is required.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eLOX Electric Strike or Magnetic Lock\u003c\/span\u003e\n      Select the correct lock based on door type, compliance requirements and fail-safe or fail-secure operation.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eExit Button \u0026amp; Door Contact\u003c\/span\u003e\n      Add request-to-exit buttons and reed switches for correct door status and access control logic.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eAccess Control Power Supply\u003c\/span\u003e\n      Use a suitable 12V DC power supply and battery backup design for reliable door operation.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eDownloads \u0026amp; Resources\u003c\/h2\u003e\n\n  \u003cp\u003eDownload the official Hikvision resources for installation planning, dimensions and technical setup.\u003c\/p\u003e\n\n  \u003cdiv class=\"cg-download-row\"\u003e\n    \u003ca class=\"cg-btn-dark\" href=\"https:\/\/www.hikvision.com\/au-en\/products\/Accessories\/Access-Control-Accessories\/Modules\/ds-k2m002x\/\" target=\"_blank\" rel=\"noopener\"\u003eView Hikvision Product Page\u003c\/a\u003e\n    \u003ca class=\"cg-btn-light\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0637\/1554\/1221\/files\/DS-K2M002X_Datasheet_20231017.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload DS-K2M002X Datasheet\u003c\/a\u003e\n    \u003ca class=\"cg-btn-light\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0637\/1554\/1221\/files\/UD35151B-B_Baseline_Access_Module_Quick_Start_Guide_V1.0_20230926.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDS-K2M002X Quick Start Guide\u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n  \u003cdiv class=\"cg-spec-section\"\u003e\n    \u003cdiv class=\"cg-spec-section__title\"\u003eHikvision DS-K2M002X · 2-Door Access Control Module\u003c\/div\u003e\n    \u003cdiv class=\"cg-table-wrap\"\u003e\n      \u003ctable class=\"cg-spec-table\"\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eModel\u003c\/td\u003e\n            \u003ctd\u003eDS-K2M002X\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eProduct Type\u003c\/td\u003e\n            \u003ctd\u003eAccess Control Expansion Module\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eOperating System\u003c\/td\u003e\n            \u003ctd\u003eMCU\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eLinked Door Capacity\u003c\/td\u003e\n            \u003ctd\u003e2 doors\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eLock Control\u003c\/td\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eExit Button Input\u003c\/td\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eDoor Contact Input\u003c\/td\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eAlarm Input\u003c\/td\u003e\n            \u003ctd\u003e4\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eAlarm Output\u003c\/td\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eTamper\u003c\/td\u003e\n            \u003ctd\u003e1\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eRS-485\u003c\/td\u003e\n            \u003ctd\u003e4 total: 2 for card readers and 2 for access controller connection\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eWiegand\u003c\/td\u003e\n            \u003ctd\u003e2 inputs, standard 26\/34-bit with custom Wiegand support\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eLinked Reader Capacity\u003c\/td\u003e\n            \u003ctd\u003e4 × RS-485 card readers using OSDP protocol and 2 × Wiegand card readers\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eIndicators\u003c\/td\u003e\n            \u003ctd\u003e6 indicators: power, running status, communication status and door status\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eBattery\u003c\/td\u003e\n            \u003ctd\u003eCharge and discharge support\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003ePower Supply\u003c\/td\u003e\n            \u003ctd\u003e12 ± 15% VDC\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003ePower Consumption\u003c\/td\u003e\n            \u003ctd\u003e≤ 50 W\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n            \u003ctd\u003e−10°C to +55°C\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eOperating Humidity\u003c\/td\u003e\n            \u003ctd\u003e0% to 90%, non-condensing\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eInstallation\u003c\/td\u003e\n            \u003ctd\u003eGuide rail installation\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003eFunctions via Controller\u003c\/td\u003e\n            \u003ctd\u003eWeb configuration, multi-factor authentication, first-person-in and multi-door interlocking via access controller\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\n  \u003cdiv class=\"cg-feature-grid\"\u003e\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eUse With a Compatible Controller\u003c\/span\u003e\n      The DS-K2M002X is an expansion module, not a standalone controller. It should be used with a compatible Hikvision access controller.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003ePlan RS-485 Addressing\u003c\/span\u003e\n      For multi-module systems, plan RS-485 wiring, addressing and module placement before installation.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eConfirm Door Hardware\u003c\/span\u003e\n      Each door still requires the correct lock, exit button, door contact and power design.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-feature-item\"\u003e\n      \u003cspan class=\"cg-feature-item-title\"\u003eProfessional Installation Recommended\u003c\/span\u003e\n      This module is intended for commercial access control systems and should be installed by a qualified security\/access control technician.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003cdiv class=\"cg-faq-grid\"\u003e\n\n    \u003cdiv class=\"cg-faq-item\"\u003e\n      \u003cstrong\u003eWhat does the Hikvision DS-K2M002X do?\u003c\/strong\u003e\u003cbr\u003e\n      It is a 2-door access control expansion module that connects to a compatible Hikvision access controller via RS-485.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-faq-item\"\u003e\n      \u003cstrong\u003eHow many doors does one DS-K2M002X support?\u003c\/strong\u003e\u003cbr\u003e\n      One DS-K2M002X supports 2 linked doors.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-faq-item\"\u003e\n      \u003cstrong\u003eIs the DS-K2M002X a standalone controller?\u003c\/strong\u003e\u003cbr\u003e\n      No. It is an expansion module and must be used with a compatible Hikvision access controller.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-faq-item\"\u003e\n      \u003cstrong\u003eDoes it support Wiegand readers?\u003c\/strong\u003e\u003cbr\u003e\n      Yes. It supports 2 Wiegand inputs with standard 26\/34-bit and custom Wiegand settings.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-faq-item\"\u003e\n      \u003cstrong\u003eDoes it support OSDP readers?\u003c\/strong\u003e\u003cbr\u003e\n      Yes. It supports RS-485 card readers using OSDP protocol.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-faq-item\"\u003e\n      \u003cstrong\u003eCan it connect to electric strikes and magnetic locks?\u003c\/strong\u003e\u003cbr\u003e\n      Yes. It provides 2 lock control outputs, but the correct lock and power supply must be selected for each door.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-faq-item\"\u003e\n      \u003cstrong\u003eWhat power does it require?\u003c\/strong\u003e\u003cbr\u003e\n      The DS-K2M002X uses 12 ± 15% VDC power.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-faq-item\"\u003e\n      \u003cstrong\u003eDoes it support door contacts and exit buttons?\u003c\/strong\u003e\u003cbr\u003e\n      Yes. It includes 2 exit button inputs and 2 door contact inputs.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-faq-item\"\u003e\n      \u003cstrong\u003eIs it suitable for large access control systems?\u003c\/strong\u003e\u003cbr\u003e\n      Yes. It is designed for expanding compatible Hikvision access control systems across multiple doors.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cg-faq-item\"\u003e\n      \u003cstrong\u003eDo you ship Australia-wide?\u003c\/strong\u003e\u003cbr\u003e\n      Yes. CCTV Guru ships genuine Hikvision access control accessories across Australia with local support.\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003ch2\u003eOrder the Hikvision DS-K2M002X from CCTV Guru\u003c\/h2\u003e\n\n  \u003cp\u003eOrder the \u003cstrong\u003eHikvision DS-K2M002X 2-Door Access Control Expansion Module\u003c\/strong\u003e from CCTV Guru for genuine Hikvision hardware, fast Australia-wide dispatch and local advice on compatible controllers, readers, locks, exit buttons, door contacts and access control power design.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Hikvision","offers":[{"title":"Default Title","offer_id":49515536908517,"sku":"DS-K2M002X","price":239.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/1554\/1221\/files\/hikvision-ds-k2m002x-2-door-access-control-module.webp?v=1781156169","url":"https:\/\/cctvguru.com.au\/products\/hikvision-ds-k2m002x-2-door-access-control-module","provider":"CCTV Guru","version":"1.0","type":"link"}