{"product_id":"apc-bx1600mi-az-back-ups-1600va-avr-4-australian-outlets","title":"APC BX1600MI-AZ — Back-UPS 1600VA\/900W UPS with AVR, 4 Australian Outlets, 230V","description":"\u003cdiv class=\"cg-premium-wrap\"\u003e\n\n  \u003cspan class=\"cg-badge cg-badge--desktop\" style=\"background:#3DCD58;color:#0f172a;\"\u003eAPC Back-UPS · 1600VA \/ 900W · 4 AU Outlets\u003c\/span\u003e\n  \u003cspan class=\"cg-badge cg-badge--mobile\" style=\"background:#3DCD58;color:#0f172a;\"\u003eAPC Back-UPS · 1600VA\u003c\/span\u003e\n\n  \u003ch2 class=\"cg-h2-sub\"\u003eBX1600MI-AZ Back-UPS with AVR — Australian Stock \u0026amp; APC 2-Year Warranty\u003c\/h2\u003e\n\n  \u003cp\u003eThe \u003cstrong\u003eAPC Back-UPS BX1600MI-AZ\u003c\/strong\u003e delivers \u003cstrong\u003e1600VA \/ 900W\u003c\/strong\u003e of battery backup and surge protection through \u003cstrong\u003e4 Australian AS\/NZS 3112 outlets\u003c\/strong\u003e — no adaptors or IEC leads required. Built for home offices, small business PCs, NBN modems, routers and NVRs, it uses \u003cstrong\u003eAutomatic Voltage Regulation (AVR)\u003c\/strong\u003e to smooth out brownouts and over-voltage without touching the battery, and a clear LED status display to show utility and battery condition at a glance.\u003c\/p\u003e\n\n  \u003cdiv class=\"cg-feature-strip\"\u003e\n    \u003cdiv class=\"cg-feature-pill\"\u003e\n      \u003cdiv class=\"cg-feature-pill__icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M13 2 3 14h9l-1 8 10-12h-9l1-8z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n      \u003cdiv class=\"cg-feature-pill__text\"\u003e\n        \u003cdiv class=\"cg-feature-pill__label\"\u003eCapacity\u003c\/div\u003e\n        \u003cdiv class=\"cg-feature-pill__value\"\u003e1600VA \/ 900W\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cg-feature-pill\"\u003e\n      \u003cdiv class=\"cg-feature-pill__icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003crect x=\"4\" y=\"4\" width=\"16\" height=\"16\" rx=\"2\"\u003e\u003c\/rect\u003e\u003cpath d=\"M9 9h6v6H9z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n      \u003cdiv class=\"cg-feature-pill__text\"\u003e\n        \u003cdiv class=\"cg-feature-pill__label\"\u003eOutlets\u003c\/div\u003e\n        \u003cdiv class=\"cg-feature-pill__value\"\u003e4× Australian\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cg-feature-pill\"\u003e\n      \u003cdiv class=\"cg-feature-pill__icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M3 12h4l3 8 4-16 3 8h4\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n      \u003cdiv class=\"cg-feature-pill__text\"\u003e\n        \u003cdiv class=\"cg-feature-pill__label\"\u003eRegulation\u003c\/div\u003e\n        \u003cdiv class=\"cg-feature-pill__value\"\u003eAVR Built-In\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cg-feature-pill\"\u003e\n      \u003cdiv class=\"cg-feature-pill__icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n      \u003cdiv class=\"cg-feature-pill__text\"\u003e\n        \u003cdiv class=\"cg-feature-pill__label\"\u003eSurge Rating\u003c\/div\u003e\n        \u003cdiv class=\"cg-feature-pill__value\"\u003e273 Joules\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eWhy choose the APC Back-UPS BX1600MI-AZ\u003c\/h2\u003e\n  \u003cdiv class=\"cg-feature-grid\"\u003e\n    \u003cdiv\u003e\n      \u003ch3\u003eGenuine Australian outlets\u003c\/h3\u003e\n      \u003cp\u003eFour AS\/NZS 3112 sockets let you plug in local gear directly — no IEC leads, travel adaptors or double-adaptors cluttering your setup.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n      \u003ch3\u003eAutomatic Voltage Regulation\u003c\/h3\u003e\n      \u003cp\u003eAVR corrects sustained low and high mains voltage back to a usable range without switching to battery, preserving battery life and riding through brownouts.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n      \u003ch3\u003eCold-start capability\u003c\/h3\u003e\n      \u003cp\u003ePower up connected equipment from the battery even when mains power is completely unavailable — useful during extended outages.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n      \u003ch3\u003eClear LED status display\u003c\/h3\u003e\n      \u003cp\u003eAt-a-glance indicators show on-line and on-battery states plus fault conditions, so you always know how the unit and your mains supply are behaving.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eTypical Runtime\u003c\/h2\u003e\n  \u003cdiv class=\"cg-table-wrap\"\u003e\n    \u003ctable class=\"cg-spec-table\"\u003e\n      \u003ctr\u003e\n\u003ctd\u003eFull Load (900 W)\u003c\/td\u003e\n\u003ctd\u003eApprox. 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eHalf Load (450 W)\u003c\/td\u003e\n\u003ctd\u003eApprox. 6.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eLight Load (modem\/router only)\u003c\/td\u003e\n\u003ctd\u003eUp to 240 minutes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n  \u003cp\u003eRuntimes are measured with new, fully charged batteries at a balanced resistive load. Sizing to roughly half the rated wattage gives you a far more useful runtime buffer.\u003c\/p\u003e\n\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n  \u003cdiv class=\"cg-spec-section\"\u003e\n    \u003cdiv class=\"cg-spec-section__title\"\u003eOutput\u003c\/div\u003e\n    \u003cdiv class=\"cg-table-wrap\"\u003e\n      \u003ctable class=\"cg-spec-table\"\u003e\n        \u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e1600VA \/ 900W\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e230V (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine Interactive\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eWaveform Type\u003c\/td\u003e\n\u003ctd\u003eStepped approximation to a sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±1 Hz, synced to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e4× Australian AS\/NZS 3112\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e6 ms typical, 10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cg-spec-section\"\u003e\n    \u003cdiv class=\"cg-spec-section__title\"\u003eInput\u003c\/div\u003e\n    \u003cdiv class=\"cg-table-wrap\"\u003e\n      \u003ctable class=\"cg-spec-table\"\u003e\n        \u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e140 – 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±5 Hz (auto-sensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eAustralian AS\/NZS 3112 plug\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eInput Cable Length\u003c\/td\u003e\n\u003ctd\u003e1.22 m\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cg-spec-section\"\u003e\n    \u003cdiv class=\"cg-spec-section__title\"\u003eBattery \u0026amp; Runtime\u003c\/div\u003e\n    \u003cdiv class=\"cg-table-wrap\"\u003e\n      \u003ctable class=\"cg-spec-table\"\u003e\n        \u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed lead-acid, maintenance-free\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e168 VAh (136 VAh runtime)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPC RBC176\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eTypical Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 – 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eCold-Start Capable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cg-spec-section\"\u003e\n    \u003cdiv class=\"cg-spec-section__title\"\u003eManagement \u0026amp; Protection\u003c\/div\u003e\n    \u003cdiv class=\"cg-table-wrap\"\u003e\n      \u003ctable class=\"cg-spec-table\"\u003e\n        \u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eLED status display (on line \/ on battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eAudible Alarm\u003c\/td\u003e\n\u003ctd\u003eOn battery \u0026amp; low battery warning\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e273 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cg-spec-section\"\u003e\n    \u003cdiv class=\"cg-spec-section__title\"\u003ePhysical \u0026amp; Environmental\u003c\/div\u003e\n    \u003cdiv class=\"cg-table-wrap\"\u003e\n      \u003ctable class=\"cg-spec-table\"\u003e\n        \u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower (not rack-mountable)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e190 × 140 × 390 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e10.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 – 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 – 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eAcoustic Noise\u003c\/td\u003e\n\u003ctd\u003e40 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, CB, RCM · RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year APC repair or replace (Australia)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eBest Suited For\u003c\/h2\u003e\n  \u003cdiv class=\"cg-bestfor-section\"\u003e\n    \u003cdiv class=\"cg-bestfor\"\u003e\n      \u003cdiv class=\"cg-bestfor-card\"\u003e\n\u003ch4\u003eHome Office \u0026amp; PCs\u003c\/h4\u003e\n\u003cp\u003eKeeps desktops, monitors and peripherals alive long enough to save work and shut down safely.\u003c\/p\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cg-bestfor-card\"\u003e\n\u003ch4\u003eNBN, Modems \u0026amp; Routers\u003c\/h4\u003e\n\u003cp\u003eLight loads run for hours, keeping internet and phone connectivity up through short outages.\u003c\/p\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cg-bestfor-card\"\u003e\n\u003ch4\u003eCCTV \u0026amp; NVR Setups\u003c\/h4\u003e\n\u003cp\u003eProtects recorders and PoE switches from brownouts and surges that cause corrupted footage.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cg-install\"\u003e\n    \u003cul\u003e\n      \u003cli\u003eCharge the UPS for a full 8 hours before relying on it for backup runtime.\u003c\/li\u003e\n      \u003cli\u003eNever plug laser printers, heaters or other high-draw appliances into a UPS outlet.\u003c\/li\u003e\n      \u003cli\u003eSize your load to around half the 900W rating for a genuinely useful runtime buffer.\u003c\/li\u003e\n      \u003cli\u003eReplace the internal battery every 3–5 years using the APC RBC176 cartridge.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eDocumentation \u0026amp; Downloads\u003c\/h2\u003e\n  \u003cdiv class=\"cg-download-row\"\u003e\n    \u003ca class=\"cg-btn-dark\" href=\"https:\/\/www.se.com\/au\/en\/product\/download-pdf\/BX1600MI-AZ?filename=Schneider+Electric_APC-BackUPS_BX1600MI-AZ.pdf#datasheet\" target=\"_blank\" rel=\"noopener\"\u003eBX1600MI-AZ Datasheet\u003c\/a\u003e\n    \u003ca class=\"cg-btn-light\" href=\"https:\/\/download.schneider-electric.com\/files?p_enDocType=Brochure\u0026amp;p_File_Name=Back-UPS+BX-MI+Brochure+AZ.pdf\u0026amp;p_Doc_Ref=Back_UPS_BX_AZ_Brochure_EN#quick-start\" target=\"_blank\" rel=\"noopener\"\u003eAPC Back-UPS Quick Start Guide\u003c\/a\u003e\n    \u003ca class=\"cg-btn-light\" href=\"https:\/\/download.schneider-electric.com\/files?p_enDocType=User+guide\u0026amp;p_File_Name=BU-UM-990-6291B-EN.pdf\u0026amp;p_Doc_Ref=SPD_BU-UM-990-6291_EN#manual\" target=\"_blank\" rel=\"noopener\"\u003eAPC Back-UPS User Manual\u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"cg-faq-grid\"\u003e\n    \u003cdiv class=\"cg-faq-item\"\u003e\n\u003cstrong\u003eDoes it have Australian power outlets?\u003c\/strong\u003e\u003cbr\u003eYes. The BX1600MI-AZ has 4 Australian AS\/NZS 3112 outlets, so local plugs connect directly without IEC leads or adaptors.\u003c\/div\u003e\n    \u003cdiv class=\"cg-faq-item\"\u003e\n\u003cstrong\u003eHow long will it run my equipment?\u003c\/strong\u003e\u003cbr\u003eAround 1 minute at the full 900W load and about 6.5 minutes at 450W. Light loads such as a modem and router can run for up to several hours.\u003c\/div\u003e\n    \u003cdiv class=\"cg-faq-item\"\u003e\n\u003cstrong\u003eIs the output a pure sine wave?\u003c\/strong\u003e\u003cbr\u003eNo. This model produces a stepped approximation to a sine wave. If your equipment uses an active PFC power supply, choose a pure sine wave model such as the APC Smart-UPS range instead.\u003c\/div\u003e\n    \u003cdiv class=\"cg-faq-item\"\u003e\n\u003cstrong\u003eDoes it connect to a computer for automatic shutdown?\u003c\/strong\u003e\u003cbr\u003eNo. The BX1600MI-AZ has no USB or serial data port. If you need PowerChute software and automated shutdown, step up to an APC Smart-UPS model.\u003c\/div\u003e\n    \u003cdiv class=\"cg-faq-item\"\u003e\n\u003cstrong\u003eWhat is Automatic Voltage Regulation (AVR)?\u003c\/strong\u003e\u003cbr\u003eAVR corrects sustained low or high mains voltage back to a safe range without discharging the battery, which protects your gear and extends battery life.\u003c\/div\u003e\n    \u003cdiv class=\"cg-faq-item\"\u003e\n\u003cstrong\u003eWhat is the replacement battery?\u003c\/strong\u003e\u003cbr\u003eIt uses the APC RBC176 replacement battery cartridge, with a typical service life of 3 to 5 years.\u003c\/div\u003e\n    \u003cdiv class=\"cg-faq-item\"\u003e\n\u003cstrong\u003eCan I mount it in a rack?\u003c\/strong\u003e\u003cbr\u003eNo. This is a tower-form UPS and is not rack-mountable. For rack installations, consider a 2U rackmount model such as the APC Smart-UPS C.\u003c\/div\u003e\n    \u003cdiv class=\"cg-faq-item\"\u003e\n\u003cstrong\u003eHow long does it take to charge?\u003c\/strong\u003e\u003cbr\u003eTypical recharge time is 8 hours. Charge it fully before depending on it for backup runtime.\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cg-trust-strip cg-trust-strip--dark\"\u003e\n    \u003cdiv class=\"cg-trust-item\"\u003e\n      \u003cspan class=\"cg-trust-icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\u003e\u003c\/path\u003e\u003cpath d=\"m9 12 2 2 4-4\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/span\u003e\n      \u003cspan class=\"cg-trust-title\"\u003e2-Year APC Warranty\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cg-trust-item\"\u003e\n      \u003cspan class=\"cg-trust-icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003crect x=\"1\" y=\"3\" width=\"15\" height=\"13\"\u003e\u003c\/rect\u003e\u003cpolygon points=\"16 8 20 8 23 11 23 16 16 16 16 8\"\u003e\u003c\/polygon\u003e\u003ccircle cx=\"5.5\" cy=\"18.5\" r=\"2.5\"\u003e\u003c\/circle\u003e\u003ccircle cx=\"18.5\" cy=\"18.5\" r=\"2.5\"\u003e\u003c\/circle\u003e\u003c\/svg\u003e\u003c\/span\u003e\n      \u003cspan class=\"cg-trust-title\"\u003eFast AU-Wide Shipping\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cg-trust-item\"\u003e\n      \u003cspan class=\"cg-trust-icon\"\u003e\u003csvg class=\"cg-icon\" viewbox=\"0 0 24 24\"\u003e\u003cpath d=\"M21 11.5a8.38 8.38 0 0 1-.9 3.8 8.5 8.5 0 0 1-7.6 4.7 8.38 8.38 0 0 1-3.8-.9L3 21l1.9-5.7a8.38 8.38 0 0 1-.9-3.8 8.5 8.5 0 0 1 4.7-7.6 8.38 8.38 0 0 1 3.8-.9h.5a8.48 8.48 0 0 1 8 8v.5z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/span\u003e\n      \u003cspan class=\"cg-trust-title\"\u003eAU Tech Support\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":50422064513253,"sku":"BX1600MI-AZ","price":329.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/1554\/1221\/files\/apc-bx1600mi-az-back-ups-1600va-avr-australian-outlets-front.jpg?v=1784532421","url":"https:\/\/cctvguru.com.au\/products\/apc-bx1600mi-az-back-ups-1600va-avr-4-australian-outlets","provider":"CCTV Guru","version":"1.0","type":"link"}